SF6 Circuit Breaker

Your Professional SF6 Circuit Breaker Supplier

 

Hebei Yueyang Electric Power Technology Co., Ltd. belongs to Beijing Beikai Zhongdian Group (established in 2005). It is a manufacturer of high and low voltage electrical equipment that integrates R&D, production, and sales. The company's main products include isolation switches, switchgear, vacuum circuit breakers, transformers, Drop Out Fuse, lightning arresters, and other series of products, which are widely used in ports, rail transportation, new energy, power systems, and infrastructure construction. These products are exported to over 60 countries and regions worldwide

 
 
Why Choose Us

Sales Market

The company has over 20 years of experience in the high and low voltage electrical industry, and its products have been sold to multiple countries and regions such as Europe, Africa, Southeast Asia, and the Middle East.

Production Equipment

Our company is equipped with 20 lathes, 10 universal cleaning machines, 8 drilling and washing machines, 5 punching machines, 9 experimental benches, 5 detectors, etc., to provide a guarantee for the high-precision production of products.

Our Certification

The company has passed the ISO9001 series system certification.

 

Focus on Product Innovation

In order to comply with the development trend of the international market, the company continuously adheres to product innovation and technological innovation.

 

Specification

 

Main

Range of product

SF

Product or component type

Circuit-breaker

Device short name

SF1

Standards

IEC 62271-100:2012
GOST-R 52565:2006

Network frequency

50/60 Hz

Network type

AC

Rated switching sequence

O - 3 min - CO - 3 min - CO
O - 0.3 sec - CO - 15 sec - CO
O - 0.3 sec - CO - 3 min - CO

Type of mechanism

Spring return, RI type

 

Complementary

Poles description

3P

Control type

Push-button

Mounting mode

Rolling frame
Fixed

Protection type

Without protection

Maximum charging time

15 s

Operating time

< 60 ms

Maximum breaking time

75 ms

Maximum closing response time

100 ms

Mechanical endurance

10000 cycles M2

Electrical endurance

E2

Technology type

SF6 gas

Creepage distance

470 mm input to output
400 mm phase to earth

Pole distance

380 mm input to output
230 mm phase to earth
280 mm phase to phase
380 mm phase to phase
220 mm phase to phase
250 mm phase to phase
350 mm phase to phase

Product weight

88 kg

Height

750 mm A1
750 mm B1
745 mm C1

Width

365 mm A1
365 mm B1
1260 mm C1

Depth

1560 mm A1
1560 mm B1
565 mm C1

 

Environment

Product certifications

IEC
GOST

Ambient air temperature for storage

-40…70 °C

Ambient air temperature for operation

-5…40 °C

 

Advantages Of SF6 Circuit Breaker

 

LW36-126 Outdoor High Voltage AC Sulfur Hexafluoride Circuit Breaker

• Sulphur hexafluoride or SF6 gas has a superior arc quenching property that is 100 times more effective than air.
• The arcing time is very short.
• SF6 has high dielectric strength due to electronegativity. It increases with an increase in pressure.
• Due to high dielectric strength, the required contact separation is small to prevent arc restriking.
• Due to High dielectric strength, it can interrupt large current.
• It has a compact design. Thus requires small space and cost for installation.
• SF6 gas can handle all kinds of switching phenomena.
• SF6 CB has a closed circuit gas system with no leakage. Therefore, it can be installed in any kind of extreme environment.
• Due to the closed-circuit gas system, there is no problem of moisture.
• The dielectric strength does not reduce because no carbon particles are formed with arcing.
• It does not require an expensive and bulky air compressing system except for the double pressure type which is obsolete.
• The operation of SF6 CB is noiseless.
• SF6 gas is non-toxic in its pure state.
• SF6 gas is non-flammable, thus no chance of fire hazards.
• Since its operation is flawless, it requires less maintenance.

Types of SF6 Circuit Breaker
 

Non-puffer type
The first invented circuit breaker or CB is Nonpuffer type SF6 that does not contain the puffer cylinder. The working principle of this circuit breaker is similar to air blast CB.

 

Single pressure puffer type
This type of SF6 CB mainly contains the puffer cylinder, which is a variable hollow cylinder. This cylinder works like a bridge between the two stable contacts. It slides axially upward & downward through the contacts to make & break the contact among the two stable contacts.
In this type of CB, the SF6 gas can be compressed through the moving cylinder & the gas can be released throughout a nozzle while the arc is extinguished. This type of circuit breaker is very popular for a wide range of voltages which ranges from 13.6 kV – to 760 kV.

 

Double pressure puffer type
Double pressure puffer type SF6 circuit breaker includes compressed SF6 gas within a cylinder for quenching the arc. In this CB, the SF6 gas can be released from the high-pressure system to the low-pressure system using a nozzle throughout the process of arc extinction. This type of design is outdated, so not used anymore.

Applications Areas of SF6 Circuit Breaker
 

• These CBs are used to protect very high voltage-based circuits up to 800 kV.
• It can depower & break a high voltage-based circuit for any type of maintenance & inspection.
• These CBs protect distribution systems & power transmission. These are used in power grids & power generation plants.
• Power distribution & control.
• Used in power circuits for Line protection.
• Used in rectifier and capacitor circuits
• Used in transformer protection.

LW36-126/T3150-40 High Voltage AC SF6 Tank Circuit Breaker
 

Our Certificate

 

productcate-1-1productcate-1-1productcate-1-1productcate-1-1

productcate-1-1productcate-1-1productcate-1-1productcate-1-1productcate-1-1productcate-1-1

 

Our Services
 

Pre sale service

a. Make technical solution
b. Send quotation, technical data sheet and drawing
c. Prepare power transmission plan, testing plan and shipment plan

 

 

 

In sale service

a. Supervise the manufacturing schedule totally in accordance with the plan
b. Send photos to customer during every manufacturing process(hold point)
c. Inform the customer one week before testing.
d. Quick response within 12 hours any time.

 

FAQ

Q: Why SF6 is used in Breaker?

A: The reasons to use SF6 gas in circuit breakers are non-flammability, high electrical insulating properties, non-toxicity, competitive cost & low maintenance.

Q: Is SF6 flammable?

A: SF6 is non-flammable with high chemical stability and it is obtained through chemical reactions in between sulfur & fluorinated gas.

Q: When would you use a vacuum circuit breaker?

A: Vacuum CBs are mainly used where system voltage levels are up to 72 kV.

Q: What is the purpose of SF6 gas in circuit breakers?

A: The purpose of SF6 gas in the CB is to extinguish the arc. It is a dielectric gas available with arc quenching & superior insulating properties.

Q: What is the pressure of SF6 gas in the circuit breaker?

A: The pressure of SF6 gas in CB is about 2.8 kg/cm2

Q: How do you maintain a SF6 circuit breaker?

A: Gas leakage detectors are effective at doing this. Gradient capacitors that are part of the circuit breaker must be inspected monthly for oil leaks. Plug any leaks if you find any. Every three to four years, the dew point of SF6 should be tested using a dew point metre or hygrometer.

Q: What is the current range of a SF6 circuit breaker?

A: They are generally used at the outlet of high-power generators (30 MVA to 1800 MVA) in order to protect them in a reliable, fast and economic manner. Such circuit breakers have high carrying current rating (4 kA to 40 kA), and have a high breaking capacity (50 kA to 275 kA).

Q: What is the current range of a SF6 circuit breaker?

A: In Double pressure SF6 circuit breakers the gas is stored at two different pressure levels: high pressure (around 20 bar) and low pressure (around 3-4 bar). This design provides better control over the release of SF6 gas during circuit breaker operation.

Q: What is lockout in SF6 circuit breaker?

A: When the SF6 gas pressure drops to the second alarm value, the density relay transmits a lockout pressure data signal, simultaneously cutting off the power switch tripping control circuit to achieve a lock-out. The SF6 circuit breaker uses SF6 gas as the insulating material and arc-extinguishing material.

Q: What is the voltage range of a SF6 circuit breaker?

A: The SF6 circuit breakers are most effectively used as a hv circuit breaker or for high voltage applications. They are also suited for medium voltages. SF6 gas circuit breaker has a voltage range from 33KV to 800 kV and even more.

Q: What is the maintenance of SF6 circuit breaker?

A: The SF6 circuit breaker must check whether there is SF6 gas leakage, such as an unnecessary SF6 low gas pressure alarm. This is effectively completed by the gas leakage detector. If the circuit breaker is equipped with gradient capacitor, its oil leakage must be checked every month.

Q: What is the time of interruption for a SF6 circuit breaker?

A: Most high-voltage SF6 gas circuit breakers (GCBs) have interrupting times of about 3 to 5 electrical cycles or about 50 to 80 ms for a 60 Hz power system.

Q: What is the low pressure alarm on SF6?

A: The first alarm is a low-pressure alarm that serves as a warning that SF6 gas density has decreased approximately half way to the lockout pressure.

Q: What are the failure modes of breakers?

A: There are two main failure modes of a breaker; failure to trip, and failure to clear. Some BFP schemes cover additional failure modes such as loss of dielectric material/pressure, loss of energy in its mechanics, and contact flashover.

Q: What are the failure modes of breakers?

A: There are two main failure modes of a breaker; failure to trip, and failure to clear. Some BFP schemes cover additional failure modes such as loss of dielectric material/pressure, loss of energy in its mechanics, and contact flashover.

Q: What is the working principle of SF6 circuit breaker?

A: The displacement of the moving contacts is synchronized with the valve which enters the high-pressure SF6 gas in the arc interrupting chamber at a pressure of about 16kg/cm^2.Jul

Q: What is the breaking capacity of SF6 circuit breaker?

A: 72.5 Kv 2500 A SF6 Circuit Breaker, Making Capacity: 79 Ka, Breaking Capacity: 31.5 Ka.

Q: What is the maintenance schedule for a circuit breaker?

A: Circuit Breaker Maintenance Checklist | ServiceChannel
High-voltage circuit breakers should be inspected every six to 12 months, while medium-voltage circuit breakers should undergo maintenance annually or after every 2,000 operations.

Q: What is the minimum interrupting rating of a circuit breaker?

A: Miniature circuit breakers and fuses may be rated to interrupt as little as 85 amperes and are intended for supplementary protection of equipment, not the primary protection of a building wiring system. In North American practice, approved general-purpose low-voltage fuses must interrupt at least 10,000 amperes.

Q: What is the use of arcing horn in SF6 circuit breaker?

A: The arced horn is a spark quenching device. When contacts of breaker start separating, an arc is formed at the contact point. The horn, which starts from the contacts and goes on broadening towards outside, guides this arc towards outer and broader end, by sheer nature of arc properties.

As one of the leading sf6 circuit breaker manufacturers and suppliers in China, we warmly welcome you to buy cheap sf6 circuit breaker for sale here from our factory. All customized products are with high quality and low price.

sf6 circuit breaker for business growth requirements, medium voltage sf6 circuit breaker, high voltage sf6 circuit breaker