Overview
LW16-40.5 outdoor sulfur hexafluoride circuit breaker is an outdoor device used in AC 50Hz three-phase power systems. It is used for control and protection in industrial and mining enterprises, power plants and sidebands. This product can be operated frequently and can be used as a contact circuit breaker and a circuit breaker for capacitor banks and reactor banks. The built-in current transformer can be used for measurement and protection. It can directly replace the SW2-35 oil-less circuit breaker. Equipped with a transition bracket, it can replace various types of oil-rich circuit breakers. It is an ideal oil-free circuit breaker in the 35KV power system. device.
LW16-40.5 circuit breaker is equipped with CT14-A AC and DC dual-purpose spring operating mechanism.
Technical Parameters
|
Project |
Unit |
Value |
||
|
Rated voltage |
KV |
40.5 |
||
|
Rated insulation level |
1min power frequency withstand voltage |
KV |
95 |
|
|
Lightning impulse withstand voltage |
KV |
185 |
||
|
Rated frequency |
Hz |
50 |
||
|
Rated current |
A |
1600,2000 |
||
|
Rated short circuit breaking current |
KA |
25 (reclosing), 31.5 (single point) |
||
|
Rated short circuit making current (peak value) |
KA |
63 |
||
|
Rated short-time withstand current |
KA |
25 |
||
|
Rated short circuit duration |
S |
4 |
||
|
Rated peak withstand current |
KA |
63 |
||
|
Rated operating sequence |
O-0.3S-CO-180S-CO |
|||
|
Rated breaking current of a single capacitor bank |
A |
400 |
||
|
Rated out-of-step breaking current |
KA |
6.3 |
||
|
Rated out-of-phase breaking current |
KA |
21.75 |
||
|
Mechanical life test |
times |
3000 |
||
|
Rated current cumulative breaking times |
times |
2000 |
||
|
Rated short circuit breaking current (25KA) cumulative breaking times |
times |
21 |
||
|
Gate opening time |
At rated or maximum operating voltage |
S |
≤0.06 |
|
|
at minimum operating voltage |
S |
≤0.1 |
||
|
Closing time |
S |
≤0.15 |
||
|
Rated pressure of SF6 gas (gauge pressure 20℃) |
MPa |
0.6±0.015 |
||
|
SF6 gas supply alarm pressure (gauge pressure 20℃) |
MPa |
0.55±0.015 |
||
|
Minimum functional pressure of SF6 gas (gauge pressure 20℃) |
MPa |
0.52±0.015 |
||
|
SF6 gas annual leakage rate |
%/year |
≤1 |
||
|
SF6 gas trace moisture content |
V/V |
≤150×10-6 |
||
|
CT14-A mechanism opening and closing coil rated voltage |
AC |
V |
220 |
|
|
DC |
110,220 |
|||
|
CT14-A mechanism energy storage motor rated voltage |
AC |
V |
220,380 |
|
|
DC |
110,220 |
|||
|
SF6 gas weight |
Kg |
Normal: 2.5, with CT: 6, with extra height, CT: 8 |
||
|
Circuit breaker weight |
Kg |
1000 |
||
|
Short circuit external insulation leakage ratio distance |
mm/KV |
≥31 |
||
|
Porcelain sleeve leakage distance |
mm |
≥1255 |
||
|
Conductive rod row spacing |
mm |
65±2 |
||
|
Minimum air insulation distance |
mm |
440 |
||
|
Three-level opening synchronicity |
ms |
≤2 |
||
|
Main circuit resistance |
μΩ |
Normal≤40 with CT≤60 |
||
|
Rigid speed (at rated voltage) |
m/s |
2.4±0.2 |
||
|
Just closing speed (at rated voltage) |
m/s |
≥2 |
||
Appearance and installation diagram

Hot Tags: lw16-40.5 outdoor sulfur hexafluoride circuit breaker, China lw16-40.5 outdoor sulfur hexafluoride circuit breaker manufacturers, suppliers, factory, indoor sf6 circuit breaker, sf6 circuit breaker for emission reduction requirements, medium voltage sf6 circuit breaker, sf6 circuit breaker for market competitiveness requirements, sf6 circuit breaker for inspection and testing, sf6 circuit breaker for energy conservation requirements