Winter Lightning Arrester Maintenance Essential Guide,Practical Points for Coping with Severe Cold

Jan 24, 2026 Leave a message

    Winter's severe cold weather poses serious challenges to the stable operation of outdoor lightning arresters. Low temperatures can cause metal components to contract, potentially leading to loose electrical connection points and increased contact resistance. The silicone rubber composite housing of the arrester loses elasticity in the cold, becoming brittle and prone to fine cracks, which compromises its sealing integrity. Ice and snow accumulation on the sheds not only adds mechanical load but may also cause abnormal electric field distribution due to uneven ice coating. Furthermore, significant day-night temperature differences can induce a "breathing effect" inside the device, potentially drawing in moisture that condenses into water droplets, severely degrading internal insulation strength. These factors collectively increase the risk of arrester failure during winter.

    Safety is the paramount prerequisite for maintenance work in cold weather. Operations must be scheduled for clear, windless periods with relatively higher daytime temperatures, strictly avoiding rainy, snowy, hailing, windy, or extremely low-temperature conditions. Before starting work, it must be confirmed that the arrester is completely disconnected from the power grid and reliably grounded, with verification through absence of voltage testing. Maintenance personnel must wear insulated protective gear suitable for cold and slippery conditions. If working at heights is necessary, ice and frost must be thoroughly cleared from ladders, platforms, and other work facilities, and safety harnesses must be used properly throughout to prevent slips and falls.

    Visual inspections in winter require extra diligence. First, use dry, soft insulated tools to gently remove icicles and snow accumulation from the insulator surface and between the sheds. Avoid forceful knocking, pouring hot water, or using open flames, as these improper methods can cause damage. After clearing, focus on examining the surface condition of the composite housing, especially at critical points like metal flange joints and sealing end caps, checking for cracks or damage caused by low-temperature embrittlement. Simultaneously, inspect the integrity of the anti-corrosion coating on all metal components, check if the grounding down conductor shows signs of being pulled or broken by frozen ground, and verify that the mounting bracket and foundation haven't become loose or tilted due to frost heave.

    Professional electrical performance testing is core to assessing the health of a lightning arrester and must be performed by qualified personnel using specialized equipment. During insulation resistance testing, note that the cold environment itself tends to yield higher readings. Results should be analyzed comprehensively against historical data and readings from other equipment in the same environment. The DC reference voltage (U1mA) and leakage current test are key projects for evaluating the valve block's performance. The ambient temperature must be precisely recorded during testing, and results should be converted and judged based on the manufacturer's provided temperature correction curve to avoid misdiagnosis. Grounding resistance measurement is particularly important in winter, as frozen soil can significantly increase soil resistivity. Special methods, such as using extended grounding electrodes or choosing midday thaw periods, may be required to ensure the grounding resistance meets safety specifications (typically required to be ≤10 ohms), guaranteeing effective dissipation of lightning current.

    Operations and maintenance personnel should be capable of identifying fault indicators during routine inspections. Signs that suggest potentially serious defects include: longitudinal cracks or obvious damage on the arrester housing, especially composite housings; persistent wet marks or icicles at locations like flange joints after snow/ice melts; abnormally high leakage current values indicated by monitors during cold, dry weather; or a discharge counter failing to operate after known lightning activity. Upon observing any such signs, immediate reporting and arrangement for professional repair are necessary. Before the defect is resolved, monitoring of the protected equipment should be enhanced, and contingency plans should be prepared. Non-professionals are strictly prohibited from performing any disassembly or repair work on arresters that are energized or have been taken out of service but not verified as de-energized and grounded.

    To improve the operational reliability of lightning arresters during the cold season, the following management measures are recommended: Schedule two key inspections, one before winter and another after the spring thaw. For high-altitude or severely cold regions, prioritize selecting products designed for harsh climates, such as "Low-Temperature Resistant" or "Plateau Type" models, during equipment selection or replacement. Spare arresters should be stored in a controlled indoor environment with stable temperature and humidity. Before installation, they should be allowed to acclimate sufficiently to the on-site ambient temperature to mitigate temperature differences. All inspection, testing, and handling activities should be documented in detail, particularly the ambient temperature, test data, and actions taken, to form a complete equipment history record.

    It is essential to clarify the division of responsibilities: The user's routine maintenance duties primarily involve regular visual inspections, simple clearing of snow and ice, recording monitoring data, and reporting abnormal conditions. All tasks involving professional testing, fault diagnosis, work at heights, replacement, and repair must be entrusted to professional institutions possessing the relevant high-voltage work qualifications and lightning protection device testing certifications. Through professional maintenance and effective collaboration, lightning arresters can be kept in good condition throughout the harsh winter, ensuring reliable protection for the upcoming thunderstorm season.