1. Introduction to vacuum circuit breaker:
Vacuum circuit breaker is a general switching device that can be widely used for the control and protection of various types of loads. Compared with the FC circuit, the difference between the two is, in layman's terms: the circuit breaker is a generalist, while the contactor is a specialist.
Vacuum circuit breaker technical standards Vacuum circuit breakers have developed vigorously in our country in the past ten years. The products have developed from a few varieties of ZN1 to ZN5 in the past to dozens of models and varieties, with rated current reaching 5000A, breaking current reaching a good level of 50kA, and voltage reaching 35kV level.
Before the 1980s, vacuum circuit breakers were in the initial stage of development. The technology was constantly being explored and technical standards could not be formulated. It was not until 1985 that relevant product standards were formulated.
"Vacuum circuit breaker" is named because its arc extinguishing medium and the insulating medium in the contact gap after arc extinguishing are both high vacuum; it has the advantages of small size, light weight, suitable for frequent operations, and no maintenance required for arc extinguishing. It is widely used in power grids. Vacuum circuit breaker is an indoor power distribution device in a 3-10kV, 50Hz three-phase AC system. It can be used for the protection and control of electrical equipment in industrial and mining enterprises, power plants, and substations. It is especially suitable for oil-free and low-voltage applications. In places of maintenance and frequent operations, circuit breakers can be configured in central cabinets, double-layer cabinets, and fixed cabinets to control and protect high-voltage electrical equipment.
2. Introduction to FC contactor:
FC is not a circuit breaker, but a combination of contactor and fuse, referred to as FC circuit. High-voltage fuses capable of breaking short-circuit fault currents in a wide range are used in conjunction with vacuum contactors that can be operated frequently for frequent starting of motors and frequent switching of capacitors.
Due to the current limiting characteristics of the fuse and the ability to quickly clear faults, it causes minimal damage to the weak insulation (high voltage winding) of the motor, so the breaking performance is suitable for motor control; its contactor action does not require energy storage and can operate frequently and quickly , suitable for frequent operations. Therefore, the FC circuit is a switching device dedicated to protecting and controlling motor loads.