Guidelines for Winter Maintenance of Surge Arresters and Disconnect Switches

Dec 27, 2025 Leave a message

    As temperatures continue to drop, the power system faces its most challenging season. The operational condition of outdoor equipment such as surge arresters and disconnect switches directly impacts grid reliability and operational safety. The core focus of winter maintenance lies in proactively addressing two primary risks: the degradation of insulation performance due to low temperatures combined with moisture, and the jamming or seizing of mechanical components caused by material contraction and lubrication failure in the cold. Effective maintenance must be systematically carried out focusing on three levels: moisture prevention, thermal protection, and ensuring mechanical reliability.

    For surge arresters, winter threats primarily stem from seal failure and performance degradation. During inspections, special attention should be paid to their exterior: check for fine cracks in the composite housing caused by cold contraction, severe contamination on the surface of porcelain insulators (which can easily cause flashover under damp conditions), and the presence of ice accretion. Inspection of sealing points is paramount; any signs of aging indicate that moisture may have already penetrated the interior. Regarding performance monitoring, it is advisable to conduct live tests on dry, sunny afternoons, focusing on recording and comparing the values of the full current and the resistive current. If a steady upward trend in the resistive current component is observed, this often signals early-stage internal moisture ingress or valve plate aging, necessitating a shorter monitoring cycle. Concurrently, the status of the discharge counter must not be overlooked, and it should be confirmed that the alarm thresholds of the online monitoring device are set appropriately and communications are normal. Finally, ensure the connection bolts of the ground lead are tightened, check the conductor for corrosion or damage from frost heave, and guarantee that the lightning current discharge path remains unobstructed.

    Winter maintenance for disconnect switches primarily focuses on the reliability of mechanical operation and the stability of the conductive circuit. Their transmission mechanisms are typical examples of being "cold-sensitive"-standard lubricants can become viscous or even solidify in low temperatures. Therefore, before winter sets in, qualified low-temperature lubricant should be applied to all rotating parts (such as bearings and linkage bushings). Their flexibility should then be tested through several complete opening and closing cycles, listening for abnormal noises and observing whether the three-phase operation is synchronized properly. For enclosures housing motorized mechanisms, check that the sealing gaskets remain pliable and test the internal heaters and dehumidification devices to ensure they function correctly when powered. Regarding the conductive circuit, focus on checking whether the contact pressure of the contacts has decreased due to cold contraction. After cleaning any oxidation from the contact surfaces, apply a sufficient amount of freeze-resistant electrical contact compound. Simultaneously, use methods like infrared thermography to inspect all conductive connection points for abnormal heating caused by increased contact resistance. Furthermore, porcelain post insulators are prone to stress under temperature fluctuations, so carefully check their bases for any newly formed cracks. The functionality of mechanical and electrical interlock devices must also be re-verified under low-temperature conditions.

    Safety is the prerequisite for all tasks. Any maintenance requiring physical contact with the equipment must strictly adhere to safety protocols: de-energization, verification of absence of voltage, and application of grounding leads. Live testing must be performed by certified professionals using approved instruments. We strongly recommend that maintenance teams establish detailed winter equipment records, thoroughly documenting the data, photographs, and corrective actions from each inspection. Comparing annual data helps predict equipment condition trends, enabling an advancement from "preventive maintenance" to "predictive maintenance." For special environments, such as heavy icing areas, insulated pole tools and de-icing plans should be prepared in advance. For areas with severe contamination, such as coastal or industrial zones, cleaning cycles should be shortened as needed, or RTV (Room Temperature Vulcanizing) silicone coatings should be applied to insulators for pollution flashover prevention.

    In summary, facing the harsh winter, the maintenance of surge arresters and disconnect switches relies on being "proactive" and "thorough." Through the systematic checks and targeted maintenance described above, the failure rate of equipment in severe weather can be significantly reduced, providing a solid foundation for the stable operation of the power grid during the peak winter load period. This guide is derived from the collective experience of frontline maintenance operations and is intended to serve as a practical reference for your actual work.