In today's urban life, every family has a variety of household appliances. When using these appliances, people have a low sense of safety. This time, we have sorted out the use of indoor vacuum circuit breakers and what are their functions? The correct use of indoor vacuum circuit breakers can ensure the life safety of our family and relatives. Today, we will explain in detail the use of indoor vacuum circuit breakers and their functions. In order to protect the life safety of your family and friends, please read carefully. Follow the footsteps of the little rabbit and read together!
When the indoor vacuum circuit breaker is in the closed position, its insulation to the ground is borne by the supporting insulator. Once the line connected to the indoor vacuum circuit breaker has a permanent grounding fault, the circuit breaker trips and the grounding fault point is not cleared, the insulation of the electric busbar to the ground must also be borne by the vacuum gap of the circuit breaker break; when various faults are broken, the vacuum insulation gap between a pair of contacts of the break must withstand the effects of various recovery voltages without breakdown.
Therefore, the insulation characteristics of the vacuum gap have become the main research topic for increasing the voltage of the arc extinguishing chamber and developing the single-break indoor vacuum circuit breaker to a high voltage level. The expression of vacuum degree The space with a rarefied gas whose absolute pressure is lower than one atmospheric pressure is called a vacuum space. The higher the vacuum degree, the lower the gas pressure in the space. There are three ways to express the unit of vacuum degree: Torr (i.e. 1 mm mercury column height), millibar (103bar) or Pascal (Pascal: Pa). (1 Torr = 131.6Pa, 1 millibar = 100Pa) What we usually say is that the vacuum degree inside the vacuum arc extinguishing chamber must reach 10-4 Torr, which means that the gas pressure inside the arc extinguishing chamber is only "one ten-thousandth of a mm mercury column height", that is, 1.31x10-2Pa. "Paison's Theorem" is also translated as "Paschen's Law", which refers to the relationship between the gap voltage withstand strength and the gas pressure.
The relationship curve representing Paison's Theorem is "V" shaped, that is, the increase or decrease of the inflation pressure can improve the insulation strength of the inter-electrode gap. Its breakdown mechanism is still unclear, because the vacuum degree inside the vacuum interrupter is higher than 10-4 Torr. In such a rarefied air space, the free travel of gas molecules is 103mm. In such a volume of vacuum interrupter, the probability of collision is almost zero. Therefore, there will be no collision and freeing to cause the vacuum gap to break down. The "V"-shaped curve of the Paison theorem is obtained experimentally. Under the condition of uniform electric field, its gap breakdown voltage Uj can be expressed as: Uj=KLa L------gap distance; a------gap coefficient (a=1 when the gap is <5mm, a=0.5 when >5mm) It can be seen from the "V"-shaped relationship curve of the Paison theorem that when the vacuum degree reaches 103 Torr, an inflection point appears, and the curve near the inflection point becomes flat, and the breakdown voltage hardly changes. When the vacuum degree and gap distance are the same, the breakdown voltage changes with the contact electrode material. When the electrode material has high mechanical strength and high melting point, the breakdown voltage of the vacuum gap also increases accordingly.
The functions of indoor vacuum circuit breakers are:
1. Small contact opening distance. The contact opening distance of 10KV indoor vacuum circuit breakers is only about 10mm, so the operating work of the operating mechanism is small, the stroke of the mechanical part is small, and its mechanical life is long.
2. The arcing time is short and has nothing to do with the size of the switching current. It is generally only half a cycle.
3. The dielectric recovery speed of the contact gap is fast after the arc is extinguished, and the performance of breaking near-zone faults is better.
4. Since the wear amount of the dredging is small when breaking the current, the electrical life of the contact is long, the full capacity breaking is up to 30-50 times, the rated current breaking is up to more than 5000 times, and the noise is small and suitable for frequent operation.
5. Small size and light weight, suitable for breaking capacitive load current.
Due to its many advantages, it is widely used in substations. The current models are mainly: ZN12-10, ZN28A-10, ZN65A-12, ZN12A-12, VS1, ZN30, etc.
I believe that everyone has a certain grasp of the use of indoor vacuum circuit breakers and their functions. Reasonably and safely use indoor vacuum circuit breakers to maximize their utilization rate. You may not have come into contact with indoor vacuum circuit breakers before, but under the guidance of Xiaotu, everyone has a further understanding of it. Only with professional guidance and analysis can friends use indoor vacuum circuit breakers more correctly.